Skip to main content

⚡ Conexionado Variador MX2 -

➡️ Conexionado Omron MX2 Clásico:Clásico Manual MX2 - Clasico.pdf:

🔹Cableado de control:

image.png

➡️Conexionado Omron MX2 EV2:EV2 :Manual MX2 EV2.pdf

🔹Cableado de control:

¡ IMPORTANTE! - La entrada CMS del variador hay que conectarla a negativo, es decir 0v, de lo contrario el STO no funcionará y el variador nunca se pondrá en RUN.

image.pngiimage.png

➡️ Descripción de las entradas y salidas digitales:

ItemTerminal symbolTerminal nameDescriptionSpecifications

Analog Power supply

L

Input signal

Common terminal for the internal common power supply, digital input, and analog I/O terminals.


H

Frequency reference power supply

10 VDC power supply for terminal O.

Allowable current: 10 mA max.

Frequency setting input (Analog voltage input)

O

Frequency reference input

0 – 10 VDC analog voltage input (adjustable max. at 9.8 V).

Input impedance ≈ 10 kΩInput range −0.3 – +12 VDC

Frequency setting input (Analog current input)

OI

Frequency reference input

4 – 20 mA DC analog input (adjustable max. at 19.8 mA).

Input impedance ≈ 100 ΩInput range 0 – 24 mA

Sensor input (TH)

5

External thermistor input

Multi-function input 5 set to 19 (TH: PTC thermistor). Trips if thermistor ≥ 3 kΩ.

PTC type

Output

AM

Multi-function analog output (Voltage)

0 – 10 VDC analog output.

Allowable current: 2 mA max.

ItemTerminal symbolTerminal nameDescriptionSpecifications

Digital Power supply

L

Input signal

Common terminal for the internal common power supply, digital input, and analog I/O.


P24

Input signal power supply

24 VDC power supply for contact input signal.

Allowable current: 100 mA max.


P24S

Safety input signal power supply

24 VDC for safety switch contacts (source logic only).

Allowable current: 100 mA max.


PLC

Input terminal power supply

Sink logic: short to P24 / Source logic: short to L.

External supply via removed bar.


CMS

Safety input signal common

Common for safety input terminals.

Inputs 1–7

1 – 7

Multi-function inputs

7 functions selectable from 66, for sink or source logic.

ON ≥ 18 V, OFF ≤ 3 V27 VDC max, 5 mA load @ 24 V, 4.7 kΩ int. res.

Safety input

GS1 / GS2

STO input terminals

Safe torque-off inputs.

ON ≥ 15 V, OFF ≤ 5 V27 VDC max, 5.8 mA @ 27 V, 4.7 kΩ int. res.

ItemTerminal symbolTerminal nameDescriptionSpecifications

Digital Input

EA

Pulse input – A

Frequency setting pulse input (5–24 VDC).

Pulse ≤ 32 kHz10 kΩ int. res.ON ≥ 4 V, OFF ≤ 1 V, 27 VDC max


EB (7)

Pulse input – B

Set C007 = 85 (EB: rotation direction detect).

Pulse ≤ 32 kHz4.7 kΩ int. res.ON ≥ 18 V, OFF ≤ 3 V

Outputs 11–12

11 / 12

Multi-function outputs

Two functions selectable from 47. Sink or source logic.

Open collector output27 V max, 50 mA max, 4 V drop max

Safety monitor

11 (EDM)

Safety monitor output

Enabled when EDM switch is ON (safety monitor signal).

Common output

CM2

Output signal common

Common terminal for 11 and 12.

100 mA max.

Relay outputs

AL1 / AL2 / AL0

Relay output terminals

Selectable functions (47 options). SPDT contacts. Default: NC AL1–AL0, NO AL2–AL0.

AL1–AL0 250 VAC 2 A (R) / 0.2 A (L)AL2–AL0 250 VAC 1 A (R) / 0.2 A (L)Min. 100 VAC 10 mA, 5 VDC 100 mA

¡ IMPORTANTE,